Model | RPVA3-125 |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |
SMPS series are fixed output voltage, current limited battery chargers specially designed for permanent connection to genset starter batteries.
They maintain the batteries fully charged, without overcharging or gassing
The DKM-0224 is a 24 channel, 144x144mm alarm annunciator, designed to be used in energy and automation systems. Optically isolated digital inputs are equipped with noise cancelling filters and are capable of operating smoothly in high electrical noise environments. The detection delay of inputs are adjustable between 2 and 500ms. The module features 3 relay outputs rated at 5Amp.
The DKG-307 is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations.
The unit is available with MPU or CANBUS versions. The CANBUS version connects to ECU controlled electronic engines providing engine control, protection and instrumentation without extra senders.
The unit is able to initiate modem calls and send SMS messages in fault conditions through external modems
The DATAKOM model DKG-171 is a low cost, microprocessor controlled unit designed to monitor the 3-phase mains voltages, send remote start command to the generating set and make changeover of both generator and mains contactors. The genset is supposed to be controlled by a Remote Start type control unit.
The front panel mimic diagram provides information about mains and generator power availability as well as contactor positions
The DKG-155 is a microprocessor controlled unit designed to start and stop the genset manually using the key switch on the front panel.
In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.
The DATAKOM model DKG-151 is a low cost, microprocessor controlled unit designed to start and stop the genset manually using the key switch and pushbuttons on the front panel. It has high power relay outputs enabling it to interface directly with diesel gensets.
In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.
The DKG-117 is a microprocessor controlled synchroscope with programmable synch check relay in a DIN72 front panel mounted package.
The DKG-117 is mainly used in manual genset synchronization applications for synchronization checking between a genset and the genset busbar or between the genset busbar and the mains
The DKG-116 is a low cost, comprehensive unit designed to start and stop a generating set both manually and remotely.
The unit is suitable for both gasoline and diesel gensets. The standard unit controls gasoline engines. Diesel engine control is selected with a wire jumper connection.
The unit is only available in 12V version