Model | RPVA3-125 |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |
ESM-3700/1 | PROCESS CONTOLLER 3 * 7.
ESM-3700/0 | PROCESS INDECATORE 3 * 7
ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R
Dimensions | 48 mm x 48 mm 86,5 mm |
Protection Class | IP65 at front, IP20 at rear |
Installation | Fixed Installation |
Storage / Operating Temperature | 0°C…50°C |
Storage / Operating Humidity | 90 % max. (None condensing) |
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
Dimensions | 48 mm x 48 mm 86,5 mm |
Protection Class | IP65 at front, IP20 at rear |
Installation | Fixed Installation |
Storage / Operating Temperature | 0°C…50°C |
Storage / Operating Humidity | 90 % max. (None condensing) |
EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN
EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size
Designed For Generator, Pump & Fire Pump Applications
Remote start / stop capability with zero power consumption
Engine start and stop
Automatic shutdown on fault condition
Provides alarm and status information
Alarm and shutdown inputs
Provides charge alternator excitation current
Lamp test function
EAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale