Hager
-
MC325 | MCB 3P 6kA C-25A 3M
MC325 | MCB 3P 6kA C-25A 3M
Power-
Total power loss under IN9.5 W
-
Power loss per pole at In3.25 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,237 EGP1,455 EGPMC325 | MCB 3P 6kA C-25A 3M
1,237 EGP1,455 EGP -
-
MC320 | MCB 3P 6kA C-20A 3M
MC320 | MCB 3P 6kA C-20A 3M
Power-
Total power loss under IN8.7 W
-
Power loss per pole at In2.93 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,237 EGP1,455 EGPMC320 | MCB 3P 6kA C-20A 3M
1,237 EGP1,455 EGP -
-
MC316 | MCB 3P 6kA C-16A 3M
MC316 | MCB 3P 6kA C-16A 3M
Power-
Total power loss under IN8 W
-
Power loss per pole at In2.69 W
Endurance-
Electric endurance in number of cycles10000
-
Number of mechanical operations20000
1,237 EGP1,455 EGPMC316 | MCB 3P 6kA C-16A 3M
1,237 EGP1,455 EGP -
-
MC310 | MCB 3P 6kA C-10A 3M
MC310 | MCB 3P 6kA C-10A 3M
Power-
Total power loss under IN5.8 W
-
Power loss per pole at In1.95 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,237 EGP1,455 EGPMC310 | MCB 3P 6kA C-10A 3M
1,237 EGP1,455 EGP -
-
MC306 | MCB 3P 6kA C-6A 3M
MC306 | MCB 3P 6kA C-6A 3M
Power-
Total power loss under IN3.9 W
-
Power loss per pole at In1.34 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,333 EGP1,568 EGPMC306 | MCB 3P 6kA C-6A 3M
1,333 EGP1,568 EGP -
-
MC304 | MCB 3P 6kA C-4A 3M
MC304 | MCB 3P 6kA C-4A 3M
Power-
Total power loss under IN5.7 W
-
Power loss per pole at In1.91 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,584 EGP1,863 EGPMC304 | MCB 3P 6kA C-4A 3M
1,584 EGP1,863 EGP -
-
MC302 | MCB 3P 6kA C-2A 3M
MC302 | MCB 3P 6kA C-2A 3M
Power-
Total power loss under IN4.3 W
-
Power loss per pole at In1.42 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,584 EGP1,863 EGPMC302 | MCB 3P 6kA C-2A 3M
1,584 EGP1,863 EGP -
-
MC263 | MCB 2P 6kA C-63A 2M
MC263 | MCB 2P 6kA C-63A 2M
Power-
Total power loss under IN12 W
-
Power loss per pole at In6.17 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,152 EGP1,355 EGPMC263 | MCB 2P 6kA C-63A 2M
1,152 EGP1,355 EGP -
-
MC240 | MCB 2P 6kA C-40A 2M
MC240 | MCB 2P 6kA C-40A 2M
Power-
Total power loss under IN9.6 W
-
Power loss per pole at In4.92 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
772 EGP908 EGPMC240 | MCB 2P 6kA C-40A 2M
772 EGP908 EGP -
-
MC225 | MCB 2P 6kA C-25A 2M
MC225 | MCB 2P 6kA C-25A 2M
-
Frequency50 to 60 Hz
Power-
Total power loss under IN6.7 W
-
Power loss per pole at In3.5 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
772 EGP908 EGPMC225 | MCB 2P 6kA C-25A 2M
772 EGP908 EGP -
-
MC216 | MCB 2P 6kA C-16A 2M
MC216 | MCB 2P 6kA C-16A 2M
Power-
Total power loss under IN5.1 W
-
Power loss per pole at In2.61 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
772 EGP908 EGPMC216 | MCB 2P 6kA C-16A 2M
772 EGP908 EGP -
-
MC210 | MCB 2P 6kA C-10A 2M
MC210 | MCB 2P 6kA C-10A 2M
Power-
Total power loss under IN3.11 W
-
Power loss per pole at In1.57 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
772 EGP908 EGPMC210 | MCB 2P 6kA C-10A 2M
772 EGP908 EGP -