Model | RPVA3-125 |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |
SMPS series are fixed output voltage, current limited battery chargers specially designed for permanent connection to genset starter batteries.
They maintain the batteries fully charged, without overcharging or gassing
The DKG-155 is a microprocessor controlled unit designed to start and stop the genset manually using the key switch on the front panel.
In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.
The DKG-105 automatic mains failure unit is a microprocessor based digital unit offering all functions needed for the automatic control of a genset.
The unit fits into a standard 72x72mm panel meter opening and offers a very cost effective and
space saving solution for the basic genset control.
In automatic mode, the unit monitors 3 phases of the mains voltage
The DKG-114 is a low cost, microprocessor controlled generator control unit designed to start and stop the genset both manually and remotely.
The manual control is made using the pushbuttons on the front panel. The remote control is made via the remote start input signal.
In the STOP position, the DC supply is removed from the module, thus zero power consumption is achieved.
The DKG-116 is a low cost, comprehensive unit designed to start and stop a generating set both manually and remotely.
The unit is suitable for both gasoline and diesel gensets. The standard unit controls gasoline engines. Diesel engine control is selected with a wire jumper connection.
The unit is only available in 12V version
The DATAKOM model DKG-151 is a low cost, microprocessor controlled unit designed to start and stop the genset manually using the key switch and pushbuttons on the front panel. It has high power relay outputs enabling it to interface directly with diesel gensets.
In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.