  • RPVA3-125 | Double 3 digit display for operating voltage value

    Model RPVA3-125
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    3,100 EGP4,150 EGP
  • RM-FVA63

    Model RM-FVA
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    2,500 EGP3,375 EGP 26% off

    RM-FVA63

    2,500 EGP3,375 EGP 26% off Read more
  • RD-MVA

    • switch guard Reletek
    • Double 3 digit display for operating voltage value
    • Protect electrical device against overvoltage and undervoltage
    • Reset/start delay adjustable(5~600s)
    • Voltage measurement accuracy ≤1%
    • Parameters setting by keys
    • LEDs indication for overvoltage and undervoltage faults
    • 3 Module, DIN Rail mounting
    700 EGP1,200 EGP

    RD-MVA

    700 EGP1,200 EGP Read more
  • SMPS2410 | SMPS-2410 BATTERY CHARGERS

    DATAKOM SMPS series are fixed output voltage, current limited lead acid and Nickel-Cadmium battery chargers specially designed for permanent connection to genset starter batteries.
    They maintain the batteries fully charged, without overcharging or gassing. Thanks to their continuous DC outputs they may also be used in a vide range of industrial applications where DC power is required.
    When the battery voltage is below the float charge level, the charger provides constant current, nearly equal to the rated output current allowing a rapid recovery of the missing charge
    7,150 EGP13,000 EGP
  • SMPS125 | SMPS 125/245 BATTERY CHARGERS

    SMPS series are fixed output voltage, current limited battery chargers specially designed for permanent connection to genset starter batteries.

    They maintain the batteries fully charged, without overcharging or gassing

    4,350 EGP7,900 EGP
  • SMPS1210 | SMPS-1210 BATTERY CHARGERS

    DATAKOM SMPS series are fixed output voltage, current limited lead acid and Nickel-Cadmium battery chargers specially designed for permanent connection to genset starter batteries.
    They maintain the batteries fully charged, without overcharging or gassing.
    Thanks to their continuous DC outputs they may also be used in a vide range of industrial applications where DC power is required.
    When the battery voltage is below the float charge level, the charger provides constant current, nearly equal to the rated output current allowing a rapid recovery of the missing charge
    6,300 EGP11,500 EGP
  • DKM0224 | DKM-0224 Alarm Annunciator (24 channels

    The DKM-0224 is a 24 channel, 144x144mm alarm annunciator, designed to be used in energy and automation systems. Optically isolated digital inputs are equipped with noise cancelling filters and are capable of operating smoothly in high electrical noise environments. The detection delay of inputs are adjustable between 2 and 500ms. The module features 3 relay outputs rated at 5Amp.

    29,700 EGP54,000 EGP
  • DKG307 | DKG-307 AUTOMATIC MAINS FAILURE UNIT

    The DKG-307 is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations.

    The unit is available with MPU or CANBUS versions. The CANBUS version connects to ECU controlled electronic engines providing engine control, protection and instrumentation without extra senders.

    The unit is able to initiate modem calls and send SMS messages in fault conditions through external modems

    7,590 EGP13,800 EGP
  • DKG171 | DKG-171 AUTO TRANSFER SWITCH

    The DATAKOM model DKG-171 is a low cost, microprocessor controlled unit designed to monitor the 3-phase mains voltages, send remote start command to the generating set and make changeover of both generator and mains contactors. The genset is supposed to be controlled by a Remote Start type control unit.

    The front panel mimic diagram provides information about mains and generator power availability as well as contactor positions

    12,650 EGP23,000 EGP
  • DKG155 | DKG-155 MANUAL START UNIT

    The DKG-155 is a microprocessor controlled unit designed to start and stop the genset manually using the key switch on the front panel.

    In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.

    4,950 EGP9,000 EGP
  • DKG151 | DKG-151 MANUAL START UNIT

    The DATAKOM model DKG-151 is a low cost, microprocessor controlled unit designed to start and stop the genset manually using the key switch and pushbuttons on the front panel. It has high power relay outputs enabling it to interface directly with diesel gensets.

    In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.

    5,500 EGP10,000 EGP
  • DKG117 | DKG-117 SYNCHROSCOPE AND CHECK SYNCH RELAY

    The DKG-117 is a microprocessor controlled synchroscope with programmable synch check relay in a DIN72 front panel mounted package.

    The DKG-117 is mainly used in manual genset synchronization applications for synchronization checking between a genset and the genset busbar or between the genset busbar and the mains

    15,400 EGP28,000 EGP