Reletek
-
RPVA3-125 | Double 3 digit display for operating voltage value
Model RPVA3-125 Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 3,100 EGP4,150 EGPRPVA3-125 | Double 3 digit display for operating voltage value
3,100 EGP4,150 EGP -
RD-MVA
- switch guard Reletek
- Double 3 digit display for operating voltage value
- Protect electrical device against overvoltage and undervoltage
- Reset/start delay adjustable(5~600s)
- Voltage measurement accuracy ≤1%
- Parameters setting by keys
- LEDs indication for overvoltage and undervoltage faults
- 3 Module, DIN Rail mounting
780 EGP1,200 EGPRD-MVA
780 EGP1,200 EGP -
Telemecanique XS618B1PAL2 | Inductive proximity sensors XS, inductive sensor XS6 M18, L62mm, brass, Sn8mm, 12…48 VDC, cable 2 m
Telemecanique XS630B1PBL2 | Inductive proximity sensors XS, inductive sensor XS6 M18, L62mm, brass, Sn8mm, 12…48 VDC, cable 2 m
2,253 EGP4,251 EGP -
Telemecanique XS630B1PBL2| Inductive proximity sensors XS, inductive sensor XS6 M30, L62mm, brass, Sn15mm, 12…48 VDC, cable 2 m
Telemecanique XS630B1PBL2| Inductive proximity sensors XS, inductive sensor XS6 M30, L62mm, brass, Sn15mm, 12…48 VDC, cable 2 m
2,613 EGP4,930 EGP -
Telemecanique XS230BLPBL2 | Inductive sensor XS2 M30, L57mm, brass, Sn15mm, 12..24VDC, cable 2m
Telemecanique XS230BLPBL2 | Inductive sensor XS2 M30, L57mm, brass, Sn15mm, 12.24VDC, cable 2m
830 EGP1,566 EGP -
Telemecanique XS218BLNAL2 | Inductive sensor XS2 M18, L53mm, brass, Sn8mm, 12.24VDC, cable 2m
Telemecanique XS218BLNAL2 | Inductive sensor XS2 M18, L53mm, brass, Sn8mm, 12.24VDC, cable 2m
700 EGP1,320 EGP -
Telemecanique XS118BLPAM12 | Inductive sensor XS1 M18, L64mm, brass, Sn5mm,12..24VDC, M12
Telemecanique XS118BLPAM12 | Inductive sensor XS1 M18, L64mm, brass, Sn5mm, 12.24VDC, M12
759 EGP1,517 EGP -
Telemecanique XCMD21F2L1 | Limit switch, Limit switches XC Standard, XCMD, M12 steel roller plunger, 1NC+1 NO, snap, 1 m
Telemecanique XCMD21F2L1 | Limit switch, Limit switches XC Standard, XCMD, M12 steel roller plunger, 1NC+1 NO, snap, 1 m
3,771 EGP7,542 EGP -
Telemecanique XCKN2139G11 | Limit switch, Limit switches XC Standard, XCKN, 50 mm, 1NC+1 NO, snap, Pg11
Telemecanique XCKN2139G11 | Limit switch, Limit switches XC Standard, XCKN, 50 mm, 1NC+1 NO, snap, Pg11
553 EGP1,043 EGP -
Telemecanique XCKJ10559 | Limit switch, XC Standard, XCKJ, thermoplastic round rod lever 6 mm, 1NC+1 NO, snap, Pg13
Telemecanique XCKJ10559 | Limit switch, XC Standard, XCKJ, thermoplastic round rod lever 6 mm, 1NC+1 NO, snap, Pg13
3,265 EGP6,160 EGP -
429 EGP
809 EGP -
814 EGP
1,535 EGP