Reletek
-
HGM250S3P200 | Hyundai HGM125S-3P200 Compact Switch 200A. 25kA TM Unadjusted
HGM250S3P200 | Hyundai HGM125S-3P200 Compact Switch 200A. 25kA TM Unadjusted
2,926 EGP3,800 EGPHGM250S3P200 | Hyundai HGM125S-3P200 Compact Switch 200A. 25kA TM Unadjusted
2,926 EGP3,800 EGP -
HGM250S3P250 | Hyundai HGM125S-3P250 Compact Switch 250A. 25kA TM Unadjusted
HGM250S3P250 | Hyundai HGM125S-3P250 Compact Switch 250A. 25kA TM Unadjusted
2,926 EGP3,800 EGPHGM250S3P250 | Hyundai HGM125S-3P250 Compact Switch 250A. 25kA TM Unadjusted
2,926 EGP3,800 EGP -
RPVA3-125 | Double 3 digit display for operating voltage value
Model RPVA3-125 Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 3,100 EGP4,150 EGPRPVA3-125 | Double 3 digit display for operating voltage value
3,100 EGP4,150 EGP -
HGC100 | Magnetic Contactor (HGC)
HGC100 | Magnetic Contactor (HGC)
Enhanced Safety
Front Protection Cover
˙Minimize foreign input
˙Prevent unexpected operation due to user’s error
Sealed Structure of Mounting Hole f or Auxiliar y Devices
˙Obstructed by contact bridge when MC is ON / OFF3,312 EGP4,301 EGPHGC100 | Magnetic Contactor (HGC)
3,312 EGP4,301 EGP -
HGC115 | Hyundai Magnetic Contactor HGC115
HGC115 | Hyundai Magnetic Contactor HGC115
Model: HGC115
Rated Insulation Voltage[Ui:] :1,000 V
Rated Operational Voltage[Ue] :1000 V
Rated Impulse Withstand Voltage[Uimp]
:8 kW
Rated Thermal Current [ Ith ] (AC1) :400 A
Mounting Method: Screw
Contacts:
Main – 2NO2NC
Auxilliary – 2NO2NC
Dimensions: 163 x 243 x 203 mm3,619 EGP4,700 EGPHGC115 | Hyundai Magnetic Contactor HGC115
3,619 EGP4,700 EGP -
HGM250L3P200 | HGM250-L3P200F HYUNDAI INT. AUT. HGM250 3P, 55KA 380/415V, 160-200A, LTD 0.8-1XIN, INST 10XIN
HGM250L3P200 | HGM250-L3P200F HYUNDAI INT. AUT. HGM250 3P, 55KA 380/415V, 160-200A, LTD 0.8-1XIN, INST 10XIN
3,678 EGP4,777 EGP -
HGC130 | Hyundai Magnetic Contactor HGC130
HGC130 | Hyundai Magnetic Contactor HGC130
Contacts:
Main – 2NO2NC
Auxilliary – 2NO2NC
Dimensions/ AC/ DC: 103 x 155 x 145.1 mm
Weight/ AC/ DC: 2.7kg3,812 EGP4,951 EGPHGC130 | Hyundai Magnetic Contactor HGC130
3,812 EGP4,951 EGP -
BC5A | BC-5A Hi-Efficiency Battery Charger
BC-5A series are state of the art battery chargers featuring very high efficiency and low cost in a compact DIN rail mounted plastic package. Chargers are designed to withstand high levels of disturbances found in the harsh automotive environment. Chargers are practically impossible to destroy, having overload, short circuit, high temperature and reverse battery protections.
4,290 EGP7,800 EGPBC5A | BC-5A Hi-Efficiency Battery Charger
4,290 EGP7,800 EGP -
SMPS125 | SMPS 125/245 BATTERY CHARGERS
SMPS series are fixed output voltage, current limited battery chargers specially designed for permanent connection to genset starter batteries.
They maintain the batteries fully charged, without overcharging or gassing
4,350 EGP7,900 EGPSMPS125 | SMPS 125/245 BATTERY CHARGERS
4,350 EGP7,900 EGP -
HGC150 | Hyundai Magnetic Contactor HGC150
HGC150 | Hyundai Magnetic Contactor HGC150
Contacts:
Main – 2NO2NC
Auxilliary – 2NO2NC
Dimensions/ AC/ DC: 138 x 204 x 174.2 mm
Weight/ AC/ DC: 2.7kg4,813 EGP6,250 EGPHGC150 | Hyundai Magnetic Contactor HGC150
4,813 EGP6,250 EGP -
DKG155 | DKG-155 MANUAL START UNIT
The DKG-155 is a microprocessor controlled unit designed to start and stop the genset manually using the key switch on the front panel.
In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved.
4,950 EGP9,000 EGPDKG155 | DKG-155 MANUAL START UNIT
4,950 EGP9,000 EGP -
DKG105 | DKG-105 AUTOMATIC MAINS FAILURE UNIT
The DKG-105 automatic mains failure unit is a microprocessor based digital unit offering all functions needed for the automatic control of a genset.
The unit fits into a standard 72x72mm panel meter opening and offers a very cost effective and
space saving solution for the basic genset control.In automatic mode, the unit monitors 3 phases of the mains voltage
5,390 EGP9,800 EGPDKG105 | DKG-105 AUTOMATIC MAINS FAILURE UNIT
5,390 EGP9,800 EGP