Meanwell
-
HGC75 | Hyundai Magnetic Contactor HGC75
HGC75 | Hyundai Magnetic Contactor HGC75
Contacts:
Main – 1NO1NC or 2NO2NC
Auxilliary – 2NO2NC
Dimensions/ AC: 70 x 146 x 153 mm
Weight/ AC: 1.3kg
Dimensions/ DC: 70 x 146 x 153 mm
Weight/ DC: 1.3kg2,349 EGP3,050 EGP -
XLG-200-12-A | AC-DC Single output LED driver Constant Power Mode with built-in PFC
AC-DC Single output LED driver Constant Power Mode with built-in PFC
Output 12Vdc at 16A
Metal housing design; IP67
Built-in potentiometer
2,400 EGP -
EDR-120-12 | AC-DC Industrial DIN rail power supply; Output 12V at 10A; metal case
AC-DC Industrial DIN rail power supply; Output 12V at 10A; metal case
- Output voltage: 12VDC
- Output current: 10A
- Output power: 120W
2,444 EGP4,887 EGP -
ESM-9910/1/J | J 9X9 1RELAY Temperature Controller
ESM-9910/1/J | J 9X9 1RELAY Temperature Controller
- ESM-XX10
- Digital ON/OFF Temperature Control Device
- ON/OFF Control Form
- Selectable Heating and Cooling Function
- PTC, NTC, PT-100, PT-1000 thermoresesistances input types
2,459 EGP4,240 EGP -
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,459 EGP4,240 EGP -
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
Dimensions 48 mm x 48 mm 86,5 mm Protection Class IP65 at front, IP20 at rear Installation Fixed Installation Storage / Operating Temperature 0°C…50°C Storage / Operating Humidity 90 % max. (None condensing) 2,494 EGP4,300 EGP -
RM-FVA63
Model RM-FVA Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 2,500 EGP3,375 EGP26% off -
EE804 | HAGER Detector 360° wall mounted
EE804 | HAGER Detector 360° wall mounted
2,536 EGP2,983 EGP -
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,552 EGP4,400 EGP -
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,552 EGP4,400 EGP -
HGC85 | Hyundai Magnetic Contactor HGC85
HGC85 | Hyundai Magnetic Contactor HGC85
Contacts:
Main – 1NO1NC or 2NO2NC
Auxilliary – 2NO2NC
Dimensions/ AC: 70 x 146 x 153 mm
Weight/ AC: 1.3kg
Dimensions/ DC: 70 x 146 x 153 mm
Weight/ DC: 1.3kg2,657 EGP3,451 EGP -
EPN525 | Latching relay 2NC+2NO 230V
EPN525 | Latching relay 2NC+2NO 230V
2,720 EGP3,200 EGP