Model | RPVA3-125 |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |
XCKJ10511 | Limit switch, XC Standard, XCKJ, thermoplastic roller lever, 1NC+1 NO, snap action, Pg13
XS7E1A1PAL2 | Inductive proximity sensors XS, inductive sensor XS7 26x26x13, PBT, Sn10mm, 12…24 VDC, cable 2 m
XS608B1PAM12 | Inductive proximity sensors XS, inductive sensor XS6 M8, L62mm, stainless, Sn2.5 mm, 12…48 VDC, M12
XCKJ167 | Limit switch, XC Standard, XCKJ, steel roller plunger reinforced, 1NC+1 NO, snap, Pg13
XCKJ10541 | Limit switch, XC Standard, XCKJ, thermoplastic plastic roller lever var. length, 1NC+1 NO, snap, Pg13
XS8C4A1PCG13 | Inductive proximity sensors XS, inductive sensor XS8 40x40x117, PBT, Sn20 mm, 12…48 VDC, terminals
ESM9920 | PID Temperature Controller with Universal Input (TC, RTD) TEMPRETURE CONTROLLER 9X9
ESM-7710/2/PT100 | PT100 7X7 2RELAY EMKO ESM-7710 2-point temperature controller with heating and cooling function and extension module system
XS8C4A1NCG13 | Inductive proximity sensors XS, inductive sensor XS8 40x40x117, PBT, Sn20 mm, 12…48 VDC, terminals
AC-DC Single output Industrial DIN rail power supply
Output 24Vdc at 10A