Reletek
-
EPN515 | Latching relay 1NC+1NO 230V
EPN515 | Latching relay 1NC+1NO 230V
1,275 EGP1,500 EGP -
EMN001 | Stair case time lag switch
EMN001 | Stair case time lag switch
1,329 EGP1,563 EGP -
MC306 | MCB 3P 6kA C-6A 3M
MC306 | MCB 3P 6kA C-6A 3M
Power-
Total power loss under IN3.9 W
-
Power loss per pole at In1.34 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,333 EGP1,568 EGP -
-
EPN503 | Latching relay 1NO+1NC 48V
EPN503 | Latching relay 1NO+1NC 48V
1,360 EGP1,600 EGP -
EPN518 | Latching relay 1NC+1NO 24V
EPN518 | Latching relay 1NC+1NO 24V
1,360 EGP1,600 EGP -
KB363B | Insulated busbar 3P 63A prong 10mm² 57M
KB363B | Insulated busbar 3P 63A prong 10mm² 57M
1,445 EGP1,700 EGP -
MC302 | MCB 3P 6kA C-2A 3M
MC302 | MCB 3P 6kA C-2A 3M
Power-
Total power loss under IN4.3 W
-
Power loss per pole at In1.42 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,584 EGP1,863 EGP -
-
MC304 | MCB 3P 6kA C-4A 3M
MC304 | MCB 3P 6kA C-4A 3M
Power-
Total power loss under IN5.7 W
-
Power loss per pole at In1.91 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,584 EGP1,863 EGP -
-
EH110 | Daily time switch 1 channel, analog, 3 modules
EH110 | Daily time switch 1 channel, analog, 3 modules
1,615 EGP1,900 EGP -
MC363 | MCB 3P 6kA C-63A 3M
MC363 | MCB 3P 6kA C-63A 3M
-
Frequency50 to 60 Hz
Power-
Total power loss under IN18.1 W
-
Power loss per pole at In6.24 W
Endurance-
Electric endurance in number of cycles4000
-
Number of mechanical operations20000
1,891 EGP2,225 EGP -
-
EH111 | Time switch daily cycle with reserve 3 modules
EH111 | Time switch daily cycle with reserve 3 modules
2,210 EGP2,600 EGP -
RM-FVA63
Model RM-FVA Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 2,500 EGP3,375 EGP26% off