Shop

View
Filter
  • MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric

    MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric

    920 EGP1,150 EGP
  • RPVA3-125 | Double 3 digit display for operating voltage value

    Model RPVA3-125
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    3,100 EGP4,150 EGP
  • RM-FVA63

    Model RM-FVA
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    2,500 EGP3,375 EGP 26% off

    RM-FVA63

    2,500 EGP3,375 EGP 26% off Read more
  • RD-MVA

    • switch guard Reletek
    • Double 3 digit display for operating voltage value
    • Protect electrical device against overvoltage and undervoltage
    • Reset/start delay adjustable(5~600s)
    • Voltage measurement accuracy ≤1%
    • Parameters setting by keys
    • LEDs indication for overvoltage and undervoltage faults
    • 3 Module, DIN Rail mounting
    700 EGP1,200 EGP

    RD-MVA

    700 EGP1,200 EGP Read more
  • MY132 | MCB 1P 4.5kA C-32A 1M

    MY132 | MCB 1P 4.5kA C-32A 1M

    • Frequency
      50 to 60 Hz
    Power
    • Total power loss under IN
      1.63 W
    • Power loss per pole at In
      1.63 W
    179 EGP210 EGP
  • MY125 | MCB 1P 4.5kA C-25A 1M

    MY125 | MCB 1P 4.5kA C-25A 1M

    • Frequency
      50 to 60 Hz
    Power
    • Total power loss under IN
      1.63 W
    • Power loss per pole at In
      1.63 W
    179 EGP210 EGP
  • MY120 | MCB 1P 4.5kA C-20A 1M

    MY120 | MCB 1P 4.5kA C-20A 1M

    • Frequency
      50 to 60 Hz
    Power
    • Total power loss under IN
      1.63 W
    • Power loss per pole at In
      1.63 W
    179 EGP210 EGP
  • MY116 | MCB 1P 4.5kA C-16 A 1M

    MY116 | MCB 1P 4.5kA C-16 A 1M

    • Rating current 50°C
      9 A
    • Rating current 55°C
      8.63 A
    • Rating current 60°C
      8.33 A
    • Rating current 65°C
      8.03 A
    • Rating current 70°C
      7.73 A

     

    179 EGP210 EGP
  • SFT240 | 2-pole, 40A Centre Off Modular Changeover Switch with Top Common Point

    SFT240 | 2-pole, 40A Centre Off Modular Changeover Switch with Top Common Point

    • Electrical durability at nominal load in AC21in operating cycles
      25000
    • Electrical durability at nominal load in AC22 in operating cycles
      25000
    • Number of mechanical operations
      200000
    757 EGP890 EGP
  • MZ201 | Auxiliary contact 1C+1O 6A 240V AC

    MZ201 | Auxiliary contact 1C+1O 6A 240V AC

    Connection
    • Type of connection
      with screw
    Equipment
    • Quantity of NC contacts
      1
    • Quantity of NO contacts
      1
    1,069 EGP1,258 EGP
  • MY110 | MCB 1P 4.5kA C-10A 1M

    MY110 | MCB 1P 4.5kA C-10A 1M

    • Frequency
      50 to 60 Hz
    Power
    • Total power loss under IN
      1.63 W
    • Power loss per pole at In
      1.63 W
    Endurance
    • Electric endurance in number of cycles
      4000
    • Number of mechanical operations
      20000
    179 EGP210 EGP
  • MY106 | MCB 1P 4.5kA C-6A 1M

    MY106 | MCB 1P 4.5kA C-6A 1M

    • Frequency
      50 to 60 Hz
    Power
    • Total power loss under IN
      1.63 W
    • Power loss per pole at In
      1.63 W
    Endurance
    • Electric endurance in number of cycles
      4000
    • Number of mechanical operations
      20000
    179 EGP210 EGP
Let's Chat

Family