Shop
-
Schneider LC1D40AM7 Contactor | TeSys D- 3P(3 NO) – AC-3 – <= 440 V 40 A – 220 V AC 50/60 Hz coil
Schneider LC1D40AM7 Contactor
4,421 EGP8,502 EGP -
Schneider PKE16M434 | PratiKa wander plug – straight – 16 A – 3P + E – 380…415 V AC – IP44
Schneider PKE16M434 | PratiKa wander plug – straight – 16 A – 3P + E – 380…415 V AC – IP44
259 EGP395 EGP -
Schneider A9C20862 | Acti9, ICT 63A 2NO 220…240V 50Hz contactor
Schneider A9C20862 | Acti9, ICT 63A 2NO 220…240V 50Hz contactor
3,850 EGP6,015 EGP -
Schneider ATV12H055M2 | variable speed drive, Altivar 12, 0.55kW, 0.75hp, 200 to 240V, 1 phase, with heat sink
Schneider ATV12H055M2
8,013 EGP14,569 EGP -
ABLS1A24031 | Regulated Power Supply, 100-240V AC, 24V 3.1 A, single phase, Optimized
ABLS1A24031 | Regulated Power Supply, 100-240V AC, 24V 3.1 A, single phase, Optimized
5,662 EGP10,294 EGP -
Schneider EZ9C1263 | EASY9 2P 63A VOLTAGE RELAY
Schneider EZ9C1263 | EASY9 2P 63A VOLTAGE RELAY
1,431 EGP2,185 EGP -
MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric
MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
RPVA3-125 | Double 3 digit display for operating voltage value
Model RPVA3-125 Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 3,100 EGP4,150 EGP