  • RPVA3-125 | Double 3 digit display for operating voltage value

    RPVA3-125 | Double 3 digit display for operating voltage value

    Model RPVA3-125
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    3,100 EGP4,150 EGP
  • RM-FVA63

    RM-FVA63

    Model RM-FVA
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    2,500 EGP3,375 EGP

    RM-FVA63

    2,500 EGP3,375 EGP Read more
  • RD-MVA

    RD-MVA

    • switch guard Reletek
    • Double 3 digit display for operating voltage value
    • Protect electrical device against overvoltage and undervoltage
    • Reset/start delay adjustable(5~600s)
    • Voltage measurement accuracy ≤1%
    • Parameters setting by keys
    • LEDs indication for overvoltage and undervoltage faults
    • 3 Module, DIN Rail mounting
    700 EGP1,200 EGP

    RD-MVA

    700 EGP1,200 EGP Read more
  • ESM-3700/1 | PROCESS CONTOLLER 3 * 7.

    ESM-3700/1 | PROCESS CONTOLLER 3 * 7.

    ESM-3700/1 | PROCESS CONTOLLER 3 * 7.

    – 4 digits display
    – Easily changeable from front panel
    – 5A or 60 mV AC, DC, AC/DC input
    – Programmable scale from 5A to 9999A
    – Alarm parameters
    – Password protection for programming mode
    – Remote access,data collecting and controlling with Modbus RTU
    – AC, DC or True RMS measuring feature
    – Having CE mark according to European Norms
    4,060 EGP7,000 EGP
  • ESM-3700/0 | PROCESS INDECATORE 3 * 7

    ESM-3700/0 | PROCESS INDECATORE 3 * 7

    ESM-3700/0 | PROCESS INDECATORE 3 * 7

    3,945 EGP6,800 EGP
  • ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R

    ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R

    ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R

    Dimensions 48 mm x 48 mm 86,5 mm
    Protection Class IP65 at front, IP20 at rear
    Installation Fixed Installation
    Storage / Operating Temperature 0°C…50°C
    Storage / Operating Humidity 90 % max. (None condensing)
    2,755 EGP4,750 EGP
  • ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5

    ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5

    ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5

    Dimensions 48 mm x 48 mm 86,5 mm
    Protection Class IP65 at front, IP20 at rear
    Installation Fixed Installation
    Storage / Operating Temperature 0°C…50°C
    Storage / Operating Humidity 90 % max. (None condensing)
    2,494 EGP4,300 EGP
  • EAOM/3STP/ALT | Generator Manual Start Controller 72x72 DIN Boyut

    EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN Boyut

    EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN

    • Inputs: 3 digital, MPU.
    • Outputs: start, preheat, tachometer.
    • Dimensions of the EAOM-3-STP controller: 72×72×120 mm.
    • The size of the panel cutout for the controller: 69×69 mm.
    • IP30 protection on the front panel.
    • Weight: 130 gr.
    • Operating temperature range: -25°С…+70°С.
    • CE, GOST-R certification.

     

    4,234 EGP7,300 EGP
  • EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

    EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size

    EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size

    Designed For Generator, Pump & Fire Pump Applications
    Remote start / stop capability with zero power consumption
    Engine start and stop
    Automatic shutdown on fault condition
    Provides alarm and status information
    Alarm and shutdown inputs
    Provides charge alternator excitation current
    Lamp test function

    3,944 EGP6,800 EGP
  • EAOM-36R | Manual And Remote Start Unit With Key Switch, 72x72 DIN Size

    EAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size

    EAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size

    Accuracy: ±1%of scale
    Cold Junction Compensation: Automatically ± 0.1°C/1°C
    Sensor Break Protection: Upscale
    Sampling Cycle: 3 samples per second

    3,042 EGP5,850 EGP
  • ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller

    ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller

    ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller

    Accuracy: ±1%of scale
    Cold Junction Compensation: Automatically ± 0.1°C/1°C
    Sensor Break Protection: Upscale
    Sampling Cycle: 3 samples per second

    2,552 EGP4,400 EGP
  • ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı

    ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı

    ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı

    Accuracy: ±1%of scale
    Cold Junction Compensation: Automatically ± 0.1°C/1°C
    Sensor Break Protection: Upscale
    Sampling Cycle: 3 samples per second

    2,552 EGP4,400 EGP