Shop
-
RPVA3-125 | Double 3 digit display for operating voltage value
Model RPVA3-125 Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 3,100 EGP4,150 EGPRPVA3-125 | Double 3 digit display for operating voltage value
3,100 EGP4,150 EGP -
RD-MVA
- switch guard Reletek
- Double 3 digit display for operating voltage value
- Protect electrical device against overvoltage and undervoltage
- Reset/start delay adjustable(5~600s)
- Voltage measurement accuracy ≤1%
- Parameters setting by keys
- LEDs indication for overvoltage and undervoltage faults
- 3 Module, DIN Rail mounting
780 EGP1,200 EGPRD-MVA
780 EGP1,200 EGP -
ESM-3700/1 | PROCESS CONTOLLER 3 * 7.
ESM-3700/1 | PROCESS CONTOLLER 3 * 7.
– 4 digits display– Easily changeable from front panel– 5A or 60 mV AC, DC, AC/DC input– Programmable scale from 5A to 9999A– Alarm parameters– Password protection for programming mode– Remote access,data collecting and controlling with Modbus RTU– AC, DC or True RMS measuring feature– Having CE mark according to European Norms4,060 EGP7,000 EGPESM-3700/1 | PROCESS CONTOLLER 3 * 7.
4,060 EGP7,000 EGP -
ESM-3700/0 | PROCESS INDECATORE 3 * 7
ESM-3700/0 | PROCESS INDECATORE 3 * 7
3,945 EGP6,800 EGPESM-3700/0 | PROCESS INDECATORE 3 * 7
3,945 EGP6,800 EGP -
ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R
ECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R
Dimensions 48 mm x 48 mm 86,5 mm Protection Class IP65 at front, IP20 at rear Installation Fixed Installation Storage / Operating Temperature 0°C…50°C Storage / Operating Humidity 90 % max. (None condensing) 2,755 EGP4,750 EGPECOLITE45/2 | TEMPRETURE CONTROLLER ON-OFF 5X5 2R
2,755 EGP4,750 EGP -
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
Dimensions 48 mm x 48 mm 86,5 mm Protection Class IP65 at front, IP20 at rear Installation Fixed Installation Storage / Operating Temperature 0°C…50°C Storage / Operating Humidity 90 % max. (None condensing) 2,494 EGP4,300 EGPECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
2,494 EGP4,300 EGP -
EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN Boyut
EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN
- Inputs: 3 digital, MPU.
- Outputs: start, preheat, tachometer.
- Dimensions of the EAOM-3-STP controller: 72×72×120 mm.
- The size of the panel cutout for the controller: 69×69 mm.
- IP30 protection on the front panel.
- Weight: 130 gr.
- Operating temperature range: -25°С…+70°С.
- CE, GOST-R certification.
4,234 EGP7,300 EGPEAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN Boyut
4,234 EGP7,300 EGP -
EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size
EAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size
Designed For Generator, Pump & Fire Pump Applications
Remote start / stop capability with zero power consumption
Engine start and stop
Automatic shutdown on fault condition
Provides alarm and status information
Alarm and shutdown inputs
Provides charge alternator excitation current
Lamp test function3,944 EGP6,800 EGPEAOM/3STP | Manual and Remote Start Unit with Key Switch, 72×72 DIN Size
3,944 EGP6,800 EGP -
EAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size
EAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second3,042 EGP5,850 EGPEAOM-36R | Manual And Remote Start Unit With Key Switch, 72×72 DIN Size
3,042 EGP5,850 EGP -
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,552 EGP4,400 EGPESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
2,552 EGP4,400 EGP -
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,552 EGP4,400 EGPESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
2,552 EGP4,400 EGP -
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second2,459 EGP4,240 EGPESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
2,459 EGP4,240 EGP