Schneider LR2K0312 | Differential thermal overload relays, TeSys K, 3.7 to 5.5 A, class 10A

1,806 EGP3,473 EGP (-48%)

Out of stock

SKU: LR2K0312 Category:

Schneider LR2K0312 | Differential thermal overload relays, TeSys K, 3.7 to 5.5 A, class 10A

Schneider LR2K0312 Description

Introduction

In the realm of industrial automation and electrical systems, the Schneider LR2K0312 stands out as a vital component. Known for its reliability and efficiency, this thermal overload relay plays a crucial role in protecting motors and ensuring smooth operation. In this article, we’ll delve into the specifics of the Schneider LR2K0312, exploring its features, benefits, and applications.

What is the Schneider LR2K0312?

The Schneider LR2K0312 is a thermal overload relay designed to protect electric motors from overheating. By detecting excessive current levels, it prevents damage to the motor, ensuring longevity and optimal performance. This device is a key player in safeguarding industrial equipment, making it indispensable in various sectors.

Technical Specifications

Understanding the technical aspects of the Schneider LR2K0312 is essential for its proper application. Here are some key specifications:

  • Rated Current: 0.25 to 0.40 A
  • Voltage: Up to 690 V
  • Frequency: 50/60 Hz
  • Number of Poles: 3
  • Operating Temperature Range: -20°C to +60°C

These specifications highlight the relay’s capacity to handle different electrical loads and environmental conditions.

Design and Construction

The Schneider LR2K0312 is built with durability and efficiency in mind. Its compact design makes it easy to integrate into various systems. The relay is constructed using high-quality materials, ensuring longevity and resistance to wear and tear. Key design features include:

  • Compact Size: Facilitates easy installation in confined spaces
  • Robust Housing: Protects internal components from environmental damage
  • Clear Markings: Ensures easy identification and connection

Functionality and Operation

The operational principle of the Schneider LR2K0312 revolves around thermal detection. When the motor draws excessive current, the relay heats up. Once a critical temperature is reached, the relay trips, cutting off the power supply to prevent overheating. This simple yet effective mechanism ensures motor protection without the need for complex electronics.

Applications of Schneider LR2K0312

The Schneider LR2K0312 is widely used across various industries due to its reliability and efficiency. Common applications include:

  • Manufacturing Plants: Protecting motors in assembly lines and machinery
  • HVAC Systems: Ensuring smooth operation of heating, ventilation, and air conditioning systems
  • Water Treatment Facilities: Safeguarding pumps and motors from damage

In each of these settings, the relay plays a critical role in maintaining operational efficiency and preventing costly downtime.

Installation Process

Installing the Schneider LR2K0312 is straightforward, but it requires careful attention to detail. Here’s a step-by-step guide:

  1. Turn off Power: Ensure the power supply is completely turned off to avoid electrical shock.
  2. Mount the Relay: Secure the relay in the designated slot within the motor control panel.
  3. Connect Wires: Follow the wiring diagram to connect the relay to the motor and power supply.
  4. Adjust Settings: Set the relay according to the motor’s specifications, adjusting the dial to the appropriate current range.
  5. Test the Installation: Once installed, turn on the power and test the relay to ensure it operates correctly.

Safety Precautions

When installing or maintaining the Schneider LR2K0312, always adhere to safety guidelines. Wear protective gear, verify power is off before handling electrical components, and consult the manual for specific safety instructions.

Maintenance Tips

To ensure the Schneider LR2K0312 continues to operate efficiently, regular maintenance is essential. Here are some tips:

  • Routine Inspections: Check the relay periodically for signs of wear or damage.
  • Clean Contacts: Ensure the electrical contacts are clean and free from corrosion.
  • Test Functionality: Regularly test the relay to ensure it trips at the correct current levels.

By following these maintenance practices, you can extend the lifespan of the relay and maintain optimal motor protection.

Advantages of Using Schneider LR2K0312

The Schneider LR2K0312 offers several advantages, making it a preferred choice for many industries:

  • High Reliability: Consistently protects motors from overheating and damage.
  • Cost-Effective: Prevents costly repairs and downtime by ensuring motor safety.
  • Ease of Use: Simple design and straightforward installation process.

These benefits make the Schneider LR2K0312 a valuable component in any industrial setup.

Comparisons with Other Relays

When compared to other thermal overload relays, the Schneider LR2K0312 stands out due to its:

  • Versatility: Suitable for a wide range of applications and motor types.
  • Durability: Built to withstand harsh industrial environments.
  • Affordability: Offers excellent value for its performance and reliability.

User Reviews and Testimonials

Feedback from users highlights the effectiveness of the Schneider LR2K0312. Many users appreciate its reliability and ease of installation. Case studies show that it has significantly reduced downtime in various industrial applications, proving its worth in real-world scenarios.

Environmental Considerations

In today’s eco-conscious world, the Schneider LR2K0312 is designed with energy efficiency in mind. Its efficient operation helps reduce energy consumption, contributing to sustainability efforts. Additionally, its robust construction ensures a long lifespan, reducing the need for frequent replacements.