Schneider LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil 1 × 1,283 EGP
Subtotal: 1,283 EGP
ESM3710/PTC/AIR | PTC 3X7 SENSOR AIR Digital ON/OFF Temperature Control Device
3710/PTC/LE | PTC 3X7 SENSOR LIQUIED Digital ON/OFF Temperature Control Device
512E | Battery Charger Float charging, 67 KHz switching, Constant output voltage Current limiting, Fail (Relay) output,
ESM-7710/1/J | J 7X7 1RELAY Digital, On/Off Temperature Controller
ESM-7710/1/PT100 | PT100 7X7 1RELAY Digital ON/OFF Temperature Control DeviceESM-XX10
ESM-7710/2/J | J 7X7 2RELAY temperature controller with heating and cooling function and extension module system
ESM-7710/2/K | K 7X7 2RELAY EMKO ESM-7710 2-point temperature controller with heating and cooling function and extension module system
ESM-9910/1/J | J 9X9 1RELAY Temperature Controller
ESM-9910/1/PT100 | PT100 9X9 1RELAY Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
ECOLITE45 | TEMPRETURE CONTROLLER ON-OFF 5X5
Dimensions | 48 mm x 48 mm 86,5 mm |
Protection Class | IP65 at front, IP20 at rear |
Installation | Fixed Installation |
Storage / Operating Temperature | 0°C…50°C |
Storage / Operating Humidity | 90 % max. (None condensing) |
Model | RM-FVA |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |