Schneider C10B3TM032 | Circuit breaker ComPacT NSX100B, 25kA at 415VAC, TMD trip unit 32A, 3 poles 3d 1 × 9,011 EGP
Subtotal: 9,011 EGP
Model | RM-FVA |
---|---|
Rated Voltage | AC 220V |
Operation Voltage Range | AC 50V~400V |
Rated frequency(Hz) | 50/60Hz |
Overvoltage(>U) Setting Range | 220~300V |
Undervoltage(<U) Setting Range | 120~210V |
Hysteresis | 2% |
Reset/Start Delay | Ts: 5s~600s |
Overcurrent Faults Trip Delay Range | Ta: 5s~600s |
Overvoltage(U>) Trip Delay | <0.1s |
Undervoltage(U<) Trip Delay | ≥120V:0.5s ,<120V: 0.1s |
Overcurrent(I>) Trip Delay | In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s |
Voltage Measurement Accuracy | ≤1%(over the whole range) |
Rated insulation voltage | 400V |
Output Contact | 1NO |
Electrical Life | 10⁵ |
Mechanical Life | 10⁶ |
Protection Degree | IP20 |
(Default) Overvoltage Trip Value | Factory setting : 250V, Setting range : 220V~300V, Step : 1V |
(Default) Undervoltage Trip Value | Factory setting : 170V, Setting range : 120V~210V, Step : 1V |
(Default) Reset/Start Delay | Factory setting : 5s, Setting range : 5s~600s, Step : 1s |
(Default) Overcurrent Trip Value | Factory setting : 63A, Setting range : 5A~63A, Step : 1A |
(Default) Overcurrent Trip Delay | Factory setting : 15s, Setting range : 5s~600s, Step : 1s |
(Default) Asymmetry Trip Value | Factory setting : 50%, Setting range : 20%~99%, Step : 1% |
(Default) Continuous Overcurrent Faults Times | Factory setting : 3, Setting range : OFF-1~20, Step : 1 |
(Default) Phase Sequence Protection | Factory setting : OFF, Setting range : ON-OFF |
XUB5BPANL2 | Photoelectric sensors XU, XUB, diffuse, Sn 0.6 m, 12…24 VDC, cable 2 m
XUB5BNANM12 | Photoelectric sensors XU, XUB, diffuse, Sn 0.6 m, 12…24 VDC, M12
XUB5BPANM12 | Photoelectric sensors XU, XUB, diffuse, Sn 0.6 m, 12…24 VDC, M12
EE804 | HAGER Detector 360° wall mounted
ESM-9910/2/J | J 9X9 2RELAY Dijital On/Off Sıcaklık Kontrol Cihazı
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
ESM-9910/2/PT100 | PT100 9X9 2RELAY Digital On/Off Temperature Controller
Accuracy: ±1%of scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Sensor Break Protection: Upscale
Sampling Cycle: 3 samples per second
XS612B1MAL2 | Inductive proximity sensors XS, inductive sensor XS6 M12, L54mm, brass, Sn4mm, 24…240VAC/DC, cable 2 m
XCSDMC5915 | Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, 5 m
XUK1ARCNL2 | Photoelectric sensors XU, XUK, reflex, Sn 7 m, 24…240VAC/DC, cable 2 m
XUK5ARCNL2 | Photoelectric sensors XU, XUK, diffuse, Sn 1 m, 24…240VAC/DC, cable 2 m