Shop
-
SE-1000-48 | SE-1000-48 1000W Out 48V/20.8A
Wattage: 1000W
Input: 115/230
Output: 5, 9, 12, 15, 24, 48
L: 278
W: 12711,300 EGPSE-1000-48 | SE-1000-48 1000W Out 48V/20.8A
11,300 EGP -
MMS32K32 | Motor guard circuit breaker 24 to 32A MMS-32K – Hyundai Electric
MMS32K32 | Motor guard circuit breaker 24 to 32A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K25 | Motor guard circuit breaker 20 to 25A MMS-32K – Hyundai Electric
MMS32K25 | Motor guard circuit breaker 20 to 25A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric
MMS32K23 | Motor guard circuit breaker 17 to 23 A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K2.5 | Motor guard circuit breaker 1.6 to 2.5A MMS-32K – Hyundai Electric
MMS32K2.5 | Motor guard circuit breaker 1.6 to 2.5A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K18 | Motor guard circuit breaker 13 to 18A MMS-32K – Hyundai Electric
MMS32K18 | Motor guard circuit breaker 13 to 18A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K14 | Motor guard circuit breaker MMS-32K – Hyundai Electric
MMS32K14 | Motor guard circuit breaker MMS-32K – Hyundai Electric
920 EGP1,150 EGPMMS32K14 | Motor guard circuit breaker MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K10 | Motor guard circuit breaker MMS-32K – Hyundai Electric
MMS32K10 | Motor guard circuit breaker MMS-32K – Hyundai Electric
920 EGP1,150 EGPMMS32K10 | Motor guard circuit breaker MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
MMS32K1.6 | Motor guard circuit breaker 1 to 1.6A MMS-32K – Hyundai Electric
MMS32K1.6 | Motor guard circuit breaker 1.6 to 2.5A MMS-32K – Hyundai Electric
920 EGP1,150 EGP -
RPVA3-125 | Double 3 digit display for operating voltage value
Model RPVA3-125 Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 3,100 EGP4,150 EGPRPVA3-125 | Double 3 digit display for operating voltage value
3,100 EGP4,150 EGP -
RM-FVA63
Model RM-FVA Rated Voltage AC 220V Operation Voltage Range AC 50V~400V Rated frequency(Hz) 50/60Hz Overvoltage(>U) Setting Range 220~300V Undervoltage(<U) Setting Range 120~210V Hysteresis 2% Reset/Start Delay Ts: 5s~600s Overcurrent Faults Trip Delay Range Ta: 5s~600s Overvoltage(U>) Trip Delay <0.1s Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s Voltage Measurement Accuracy ≤1%(over the whole range) Rated insulation voltage 400V Output Contact 1NO Electrical Life 10⁵ Mechanical Life 10⁶ Protection Degree IP20 (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1% (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1 (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF 2,500 EGP3,375 EGP26% offRM-FVA63
2,500 EGP3,375 EGP26% off -
RD-MVA
- switch guard Reletek
- Double 3 digit display for operating voltage value
- Protect electrical device against overvoltage and undervoltage
- Reset/start delay adjustable(5~600s)
- Voltage measurement accuracy ≤1%
- Parameters setting by keys
- LEDs indication for overvoltage and undervoltage faults
- 3 Module, DIN Rail mounting