  • EDR-120-12 | AC-DC Industrial DIN rail power supply; Output 12V at 10A; metal case

    EDR-120-12 | AC-DC Industrial DIN rail power supply; Output 12V at 10A; metal case

    AC-DC Industrial DIN rail power supply; Output 12V at 10A; metal case

    • Output voltage: 12VDC
    • Output current: 10A
    • Output power: 120W
    2,444 EGP4,887 EGP
  • RM-FVA63

    RM-FVA63

    Model RM-FVA
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    2,500 EGP3,375 EGP

    RM-FVA63

    2,500 EGP3,375 EGP Read more
  • RPVA3-125 | Double 3 digit display for operating voltage value

    RPVA3-125 | Double 3 digit display for operating voltage value

    Model RPVA3-125
    Rated Voltage AC 220V
    Operation Voltage Range AC 50V~400V
    Rated frequency(Hz) 50/60Hz
    Overvoltage(>U) Setting Range 220~300V
    Undervoltage(<U) Setting Range 120~210V
    Hysteresis 2%
    Reset/Start Delay Ts: 5s~600s
    Overcurrent Faults Trip Delay Range Ta: 5s~600s
    Overvoltage(U>) Trip Delay <0.1s
    Undervoltage(U<) Trip Delay ≥120V:0.5s ,<120V: 0.1s
    Overcurrent(I>) Trip Delay In<Ir *<Imax: Ta; Ir *≥Imax: ≤0.1s
    Voltage Measurement Accuracy ≤1%(over the whole range)
    Rated insulation voltage 400V
    Output Contact 1NO
    Electrical Life 10⁵
    Mechanical Life 10⁶
    Protection Degree IP20
    (Default) Overvoltage Trip Value Factory setting : 250V, Setting range : 220V~300V, Step : 1V
    (Default) Undervoltage Trip Value Factory setting : 170V, Setting range : 120V~210V, Step : 1V
    (Default) Reset/Start Delay Factory setting : 5s, Setting range : 5s~600s, Step : 1s
    (Default) Overcurrent Trip Value Factory setting : 63A, Setting range : 5A~63A, Step : 1A
    (Default) Overcurrent Trip Delay Factory setting : 15s, Setting range : 5s~600s, Step : 1s
    (Default) Asymmetry Trip Value Factory setting : 50%, Setting range : 20%~99%, Step : 1%
    (Default) Continuous Overcurrent Faults Times Factory setting : 3, Setting range : OFF-1~20, Step : 1
    (Default) Phase Sequence Protection Factory setting : OFF, Setting range : ON-OFF
    3,100 EGP4,150 EGP
  • NDR-240-24 | AC-DC Single output Industrial DIN rail power supply

    NDR-240-24 | AC-DC Single output Industrial DIN rail power supply

    AC-DC Single output Industrial DIN rail power supply

    Output 24Vdc at 10A

    metal case

    3,524 EGP7,047 EGP
  • SE-1000-48 | SE-1000-48 1000W Out 48V/20.8A

    SE-1000-48 | SE-1000-48 1000W Out 48V/20.8A

    Wattage: 1000W
    Input: 115/230
    Output: 5, 9, 12, 15, 24, 48
    L: 278
    W: 127

    11,300 EGP