EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN Boyut

4,234 EGP7,300 EGP (-42%)

1 in stock

EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN

  • Inputs: 3 digital, MPU.
  • Outputs: start, preheat, tachometer.
  • Dimensions of the EAOM-3-STP controller: 72×72×120 mm.
  • The size of the panel cutout for the controller: 69×69 mm.
  • IP30 protection on the front panel.
  • Weight: 130 gr.
  • Operating temperature range: -25°С…+70°С.
  • CE, GOST-R certification.

 

SKU: EAOM/3STP/ALT Category:

EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN

Manual Start Unit use microprocessor based technology to provide integrated manual start and
fault protection in a wide range of engine applications. The module is housed in 72×72 DIN size.The module is
used to start and stop the engine, indicating the operational status and fault conditions. Automatically shutting
down the engine and indicating the engine failure by a flashing LED. User can control the engine via a two position
key switch and pushbuttons mounted on the front panel or with remote input.
The module has three application feature; ‘Generator’, ‘Pump’ or ‘Fire Pump’. (can be selected from
parameter P00).
The module can connect directly with engine, thanks to high current relay outputs.
The module has two feature for fuel. One of “energize to run” the other “energize to stop”.
The module protect the engine against fault conditions. If a fault condition occurred, the module indicate the fault
condition and shut-down the engine.
If the key switch is OFF position the module has zero power consumption to save energy. The module energizes
when the key switch position is getting ON position. If Satart button is pressed, the Conf. Out relay output (if selected
preheat output) will activate until the preheat delay is expired.
Press Start button for starting the engine. When engine is running, module will stop the cranking.
Also the module has remote start facility. Please select suitable type of remote start for your application from
program parameters. If remote start input is active the module will start the engine. If remote start is passive the unit will
stop the engine.
The module will check the alarms aftersafety on timer is expired.
Under one of this fault conditions the module will stop the engine;
– Over speed (generator application),
– Under speed(generator application),
– High Temperature,
– Low Oil Pressure,
– Shutdown (if one of conf. input selected shutdown and activated).
To reset the fault, turn the key switch to the OFF position for a few seconds.
The Charge Failure is a warning alarm so the engine continue to work under this failure condition. Also this input
supplying charge alternator excitation current.
Shutdown the engine;
If the engine fuel type is “energize to stop”, press Stop button until the engine comes to rest. After that select OFF
position of the key switch.
If the engine fuel type is “energize to run”, select OFF position of the key switch.
Important note: On the Fire Pump application; If a fault condition occurred, the module will not stop the engine.
The engine will be stopped only when the stop button was pressed or the remote stop signal was detected.
User can select the
feature from program parameters.

 

 

 

Additional information

Brands

Emko

Be the first to review “EAOM/3STP/ALT | Generator Manual Start Controller 72×72 DIN Boyut”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Let's Chat

Family

EAOM/3STP/ALT | Generator Manual Start Controller 72x72 DIN Boyut

4,234 EGP7,300 EGP (-42%)

Add to Cart